1290 Infinity II Autoscale Preparative LC/MSD System
The 1290 Infinity II Autoscale Preparative LC/MSD System is the ultimate workflow solution for direct scale-up from analytical scouting to gram-level purification of target compounds.
Agilent automated purification software enables automated method transfer from analytical to preparative-scale purification. Mass-selective fraction triggering streamlines your purification processes and helps boost laboratory efficiency.
Product details
Features
- Preparative LC/MSD System with automated combined sample injection and fraction collection enables scale-up from analytical to preparative chromatography on one single system to maximize your capacity and increase your daily throughput
- Support of automated workflows through import and export of sample sequences while focusing solely on your target compounds to minimize re-analysis time and reformulation of collected fractions
- Highly reliable and robust LC system improves your ability to manage ever-increasing workload demand
- Easy-to-change pump heads provide dynamic flow range up to 200 mL/min at maximum 600 bar for versatile application within a wide range of preparative workflows
- Control and organization of valves: Five multipurpose slots provide enhanced organization of valves, fraction delay coils, and Agilent 1290 Infinity II MS Flow Modulator for a significant increase in productivity
- Integration of all standard collection modes and compatibility with multiple trigger sources provides compatibility to existing purification methods
- Lowest delay volume to minimize peak dispersion and carry-over for the highest sample recovery and purity
- Clean software infrastructure through Agilent OpenLab CDS ChemStation for familiar and reliable operation
- Automated purification software opens the door to workflow automation to scale-up from analytical to preparative conditions based on scientific algorithms – eliminates the need for time-consuming method development to improve daily purification cycles
- Integrated leak sensor in each module shuts down the whole system; providing additional safety when detecting a leak
How it works
Technology
Specifications
Biocompatible | No |
Bioinert | No |
Column Capacity | 10 |
Column ID Reader Option | No |
Depth | 622 mm |
Flow Range | 1-200 mL/min |
Injection Range | 5-15700 µL |
Intelligent System Emulation Technology | No |
Line Voltage | 100-240 VAC |
Maximum Number of Fractions | 432 |
Maximum Number of Solvents | 4 |
Pump Type | Binary |
Special Features | Delay Sensor
Automated Delay Volume Calibration Analytical-to-preparative work |
System Pressure Operating Range | 20-600 bar |
Width | 2181 mm |