Pumping speed, operating range |
6,000 l/s air, 7,500 l/s He and H2 |
Pumping speed*, AVS 4.1(1963) |
10,000 l/s air |
Maximum throughput |
8,100 W – 9.5 T-l/s (12.7 mbar l/s) in operating range13.5 T-l/s (18.0 mbar-l/s) @ 0.01 Torr |
|
9,600 W –12.0 T-l/s (16 mbar l/s) in operating range 11.5 T-l/s (15.3 mbar-l/s) @ 0.01 Torr |
Operating range |
2 x 10-3 to <5 x 10-8 Torr at 9,600 W (1.3 x 10-3 to <6.5 x 10-8 mbar) |
Maximum forepressure |
No load – 0.65 Torr (0.85 mbar), Full Load – 0.55 Torr (0.72 mbar) |
Pump power |
8100/9600 watts |
Recommended backing pump |
≥ 80 cfm (136 m3/hr) |
Backstreaming rate**, standard cold cap |
<1.5 x 10-3 mg/cm2/min |
Warmup time |
30 minutes |
Cooldown time |
48 minutes (30 minutes with optional quick cool coil) |
Fluid charge |
3 quarts (2.8 liters) |
Electrical requirements |
3 ph, 50/60 Hz, 240/415/480 VAC |
Cooling water requirements |
1.5 gpm (300 l/hr) at 60-80 °F (15-26 °C) |
Water connections |
1⁄4 in. FPT Tee |
Recommended fluid |
DC-704 |